Conduction block of whole nerve without onset firing using combined high frequency and direct current

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

simulation of fiber conduction block using high frequency alternative current with asymmetric biphasic waveform and its mechanism of action

introduction: high frequency alternating currents is a safe, reversible and selective method for nerve conduction block that has been under study during the last decade as a treatment for the diseases involving abnormal neural impulses. however, reducing the stimulus amplitude, and the undesired onset response, as well as optimizing the stimulus parameters for more effective block is still unde...

متن کامل

Asymmetric Rectangular Waveform in Stimulation with High Frequency Alternating Current Reduces the Threshold for Neural Conduction Block

Introduction Abnormal neural impulses in the nervous system may lead to various diseases and disabilities. High frequency alternating currents (HFAC) has been used to block the propagation of such impulses and improve the symptoms or disabilities. The technique is safe, reversible, and relatively selective, and its reliability, the optimum stimulation parameters, and elimination of the onset re...

متن کامل

Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation

BACKGROUND Methods for the electrical inhibition of cardiac excitation have long been sought to control excitability and conduction, but to date remain largely impractical. High-amplitude alternating current (AC) stimulation has been known to extend cardiac action potentials (APs), and has been recently exploited to terminate reentrant arrhythmias by producing reversible conduction blocks. Yet,...

متن کامل

Electrical conduction block in large nerves: high-frequency current delivery in the nonhuman primate.

Recent studies have made significant progress toward the clinical implementation of high-frequency conduction block (HFB) of peripheral nerves. However, these studies were performed in small nerves, and questions remain regarding the nature of HFB in large-diameter nerves. This study in nonhuman primates shows reliable conduction block in large-diameter nerves (up to 4.1 mm) with relatively low...

متن کامل

Torque Control of Brushless Direct Current Motor Drives Using Single Current Sensor with High Reliability

Due to the simple structure, high torque density, low maintenance, and high efficiency, brushless direct current (BLDC) motors are widely used in automation and industrial applications. A control strategy based on single current sensor is proposed for a four-switch three-phase BLDC motor system to lower cost and improve reliability. The whole working process of the BLDC motor is divided into si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical & Biological Engineering & Computing

سال: 2010

ISSN: 0140-0118,1741-0444

DOI: 10.1007/s11517-010-0679-x