A conductimetric enzyme biosensor for uric acid detection has been developed. The uricase, as enzyme, is isolated from Candida utilis and immobilized on a nata de coco membrane-Pt electrode. The biosensor demonstrates a linear response to urate over the concentration range 1-6 ppm and has good selectivity properties. The response is affected by the membrane thickness and pH change in the range ...
متن کاملUric Acid Analysis with Uricase
Results with two ultramicro methods for plasma uric acid analysis with uricase are described: a crystal violet (gentian violet) method, modified from an automated procedure by Gochman and Schmitz [C/in. Chem. 17, 1154 (1971)] and adapted to manual analysis, and a polarographic oxygen-sensing system (Beckman Instruments,Inc.).The coefficientof variation (CV) for the crystal violet method varied ...
متن کاملCovalent immobilization of uricase inside a plastic vial for uric acid determination in serum and urine.
Uricase from Candida species was immobilized covalently onto the inner wall of a plasticized polyvinyl chloride (PVC/plastic) vial through glutraldehyde coupling with a 65.23% retention of its initial activity and a conjugation yield of 0.37 mg/cm(2). The vial-bound enzyme showed the optimum activity at pH 7.2, when incubated at 45°C for 5 min. There was a linear relationship between the immobi...
متن کاملA Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...
متن کاملAn Amperometric Biosensor for Uric Acid Determination Prepared From Uricase Immobilized in Polyaniline-Polypyrrole Film
A new amperometric uric acid biosensor was developed by immobilizing uricase by a glutaraldehyde crosslinking procedure on polyaniline-polypyrrole (pani-ppy) composite film on the surface of a platinum electrode. Determination of uric acid was performed by the oxidation of enzymatically generated H₂O₂ at 0.4 V vs. Ag/AgCl. The linear working range of the biosensor was 2.5×10-6 - 8.5×10-5 M and ...