Condition monitoring and fault diagnosis of an MR load tap changer using oil analysis data
نویسندگان
چکیده
منابع مشابه
Fault Diagnosis of On-Load Tap-Changer Based on Variational Mode Decomposition and Relevance Vector Machine
Abstract: In order to improve the intelligent diagnosis level of an on-load tap-changer’s (OLTC) mechanical condition, a feature extraction method based on variational mode decomposition (VMD) and weight divergence was proposed. The harmony search (HS) algorithm was used to optimize the parameter selection of the relevance vector machine (RVM). Firstly, the OLTC vibration signal was decomposed ...
متن کاملMachine Condition Monitoring and Fault Diagnosis Using Spectral Analysis Techniques
There is need to continuously monitor the conditions of complex, expensive and process-critical machinery in order to detect its incipient breakdown as well as to ensure its high performance and operating safety. Depending on the application, several techniques are available for monitoring the condition of a machine. Vibration monitoring of rotating machinery is considered in this paper so as d...
متن کاملInnovative Transformer Load Tap Changer Control Using Ethernet-Based Communications
This paper describes the design of a load tap changer (LTC) control for up to four parallel transformers using a modified circulating current approach. The LTC control discussed in this paper was implemented using programmable logic, math functions, and IEC 61850 communications over fiber-optic Ethernet. One LTC control is associated with each transformer. The current angle from each LTC contro...
متن کاملSolid - State On Load Tap - Changer for Transformer Using Microcontroller
The on-load tap changing (OLTC) regulators have been widely used since the introduction of electrical energy. They ensure a good regulation of the output voltage in presence of large variations of the input voltage with typical response time from several mili-seconds to several seconds. Earlier mechanical type of on load tap changers were into practice. But they had considerable limitations and...
متن کاملThermal model of oil power transformers with a tap changer
The paper presents a new method for on-line temperature calculation taking into account change in the tap changer position. The method introduces accurate calculation of the losses, depending on the current, average temperature of the winding, and tap changer position (it affects both Joules (DC) losses and stray losses). The thermal model itself is the common three-body model (for a transforme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Engineering Research
سال: 2015
ISSN: 2307-1877,2307-1885
DOI: 10.7603/s40632-015-0013-8