Computer tomography dose index measurements on a multislice CT scanner using polymer gels

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer gel dosimetry on a multislice computed tomography scanner: effect of changing parameters on CTDI.

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

متن کامل

Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner.

Recently, attempts to develop new types of swallowing function analysis with 320-detector-row multislice CT (320-MDCT) have been reported. The present report addresses (1) patient exposure, (2) operator exposure, and (3) spatial dose distribution. For dose measurement, a human-body phantom in which 303 thermoluminescent dosimeter elements were inserted and a survey meter was used. The patient p...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Variations in radiation dose between the same model of multislice CT scanner at different hospitals.

The variation in exposure factors and patient dose, between seven centres using identical multislice CT scanners, was investigated for six standard examinations. Dose values were compared with each other and the relevant diagnostic reference level (DRL) for each examination. The range in weighted CT dose index (CTDI(w)) values between the seven centres was small for abdominal scans and head sca...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...