منابع مشابه
Computer assisted orthopaedic surgery -- CAOS.
The use of computer navigation in orthopedic surgery allows for real time intraoperative feedback resulting in higher precision of bone cuts, better alignment of implants and extremities, easier fracture reductions, less radiation and better documentation than what is possible in classical orthopaedic procedures. There is no need for direct and repeated visualization of many anatomical landmark...
متن کاملRobotics and computer-assisted orthopaedic surgery.
These are just a few representative applications of the synergistic use of computer and robotic technology assisting the orthopaedic surgeon. While the individual systems are certain to change over time, the basic principles of correlating radiographic and anatomic data through a registration process, and displaying additional instrument or implant information through smart tools and surgical n...
متن کامل6 Computer-assisted Minimally Invasive Spine Surgery State of the Art 6.2 Computer-assisted Orthopaedic Surgery
With the advent of precise preand intraoperative imaging means, the development of sophisticated image data visualization, and the accessibility of submillimetric, real-time tracking of objects in space, surgical navigation systems have been created that aim at enhanced surgical accuracy and ultimately improved clinical outcome [3, 6, 9, 13, 17, 20]. Numerous studies have shown the superiority ...
متن کاملComputer-Assisted Orthopaedic Surgery and Robotic Surgery in Total Hip Arthroplasty
Various systems of computer-assisted orthopaedic surgery (CAOS) in total hip arthroplasty (THA) were reviewed. The first clinically applied system was an active robotic system (ROBODOC), which performed femoral implant cavity preparation as programmed preoperatively. Several reports on cementless THA with ROBODOC showed better stem alignment and less variance in limb-length inequality on radiog...
متن کاملComputer assisted spine surgery.
When inserting screws into a vertebral pedicle, the surgeon usually exposes the back part of the vertebra and uses his or her anatomic knowledge to align the drill in the proper direction. A slight error in direction may result in an important error in the position of the tip of the screw. This is done with no direct visibility of crucial structures (spinal cord, pleura, vessels). Statistical a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopaedic Surgery
سال: 2017
ISSN: 1757-7853
DOI: 10.1111/os.12323