Comprehensive Analysis of Electric Field Characteristics for Multi-Winding Medium Frequency Transformer
نویسندگان
چکیده
The multi-winding medium frequency transformer (MMFT) has attracted widespread attention, since its application in power electronic transformers can simplify the system structure and reduce volume weight. However, special working conditions of MMFT due to high voltage density increase difficulty insulation design for MMFT. For this issue, paper presents a comprehensive analysis electric filed characteristics First, field model is established using 2-D finite element method. Based on it, influences connection mode, core structure, hollow winding are studied, including overall distribution, maximum intensity, intensity along fixed path. results show that there differences different modes structures, which provides references design. proposed modeling method important improvement
منابع مشابه
Electric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer
The electronic power transformer (EPT) raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs) are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influe...
متن کاملA High Frequency Transformer Winding Model for FRA Applications
Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...
متن کاملComparison of Impulse Wave and Sweep Frequency Response Analysis Methods for Diagnosis of Transformer Winding Faults
Monitoring of winding faults is the most important item used to determine the maintenance status of a transformer. Commonly used methods for winding-fault diagnosis require the transformer to exit operation before testing and an external exciting signal, whether the transformer is malfunctioning or not. However, if an overvoltage signal can be regarded as a broadband excitation source for fault...
متن کاملTransfer Function of Transformer Winding for Frequency Response Analysis Based on Traveling Wave Theory
This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived...
متن کاملMedium Frequency Transformer Design and Optimization
This paper describes the technical challenges tied to modeling and design optimization of the medium frequency transformer (MFT) for power electronic applications, namely emerging solid state transformers (SSTs). A detailed analysis and modeling of the phenomena governing the MFT electrical behavior as well as limiting the operation and design range is performed. A synthesis of all these models...