Composite box girder with corrugated steel webs and trusses – A new type of bridge structure
نویسندگان
چکیده
منابع مشابه
Theoretical and Experimental Study on Natural Frequency of Externally Prestressed Box-Girder with Corrugated Steel Webs
Abstract: Based on the characteristics of box girder with corrugated steel webs, the existing prestressing force, the effect of shear deformation of composite girder on the deflection, “folding effect” in longitudinal direction of corrugate steel webs and the arrangement of external tendons were considered comprehensively. With the experiment results of five literatures integrated, N/fcA (the a...
متن کاملThe Stress-related Damping Ratio of Box Girder with Corrugated Steel Webs
In this paper, the stress-related damping ratio formula of box girder with corrugated steel webs is introduced. Using response spectrum method, an iterative algorithm is proposed to calculate the seismic response and the stressrelated damping ratio under different seismic intensities. Based on a simply supported composite box girder bridge with corrugated steel webs, the stress-related damping ...
متن کاملLoad Test and Model Calibration of a Horizontally Curved Steel Box-Girder Bridge
In this paper, full scale load test of a horizontally curved steel box-girder bridge is carried out in order to detect structural defects, which reportedly result in unwanted vibrations in nearby buildings. The bridge is tested under the passage of six heavy vehicles at different speeds, so as to determine its static and dynamic responses. A total number of one hundred and two (102) sensors are...
متن کاملDesign aspects of steel I-girders with corrugated steel webs
Corrugated web girders represent a new structural system emerged in the past two decades. The girder’s flanges provide the flexural strength of the girder with no contribution from the corrugated web which provides the girder’s shear capacity. Failure of the web occurs by steel yielding, web buckling or interactively between them. Lateral torsion and local flange buckling of corrugated web gird...
متن کاملload test and model calibration of a horizontally curved steel box-girder bridge
in this paper, full scale load test of a horizontally curved steel box-girder bridge is carried out in order to detect structural defects, which reportedly result in unwanted vibrations in nearby buildings. the bridge is tested under the passage of six heavy vehicles at different speeds, so as to determine its static and dynamic responses. a total number of one hundred and two (102) sensors are...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2018
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2018.03.047