Comparison of VBM Endoscopy Mask and Explorer Endoscopy Face Mask on Fiberoptic Intubation:A Manikin Study

نویسندگان

چکیده

2種類のファイバー挿管用内視鏡マスク,VBMエンドスコピーマスク(VEM)とインターサージカル・ブロンコスコピーマスク(IBM)の性能を比較した.マネキンに両マスクを装着し,陽圧換気をしながらファイバー挿管を行った.挿管時間,気管チューブとスコープの操作性,挿管操作前の換気量は,両マスク間に有意差を認めなかった.挿管操作により両マスクとも有意に換気量が減少したが,VEMは臨床的に問題ない程度であった.しかし,IBMでは挿管操作中のリークで換気困難となった.ファイバー挿管手技の行いやすさは両マスク間に差がなかったが,マスク換気に関して,IBMでは挿管操作中のリーク対策が必要であった.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positive pressure ventilation during fibreoptic intubation: comparison of the laryngeal mask airway, intubating laryngeal mask and endoscopy mask techniques.

BACKGROUND The efficacy of delivery of mechanical ventilation through different airway devices during fibreoptic intubation is not known. METHODS We compared the laryngeal mask airway (LMA), intubating laryngeal mask (ILM) and endoscopy mask for positive pressure ventilation (PPV) during fibreoptic intubation. In 80 adult paralysed patients, fibreoptic intubation was performed during PPV usin...

متن کامل

Comparison of the use of the laryngeal mask and face mask by inexperienced personnel.

Ten junior doctors with no postgraduate anaesthetic experience attempted to ventilate the lungs of 50 anaesthetized patients, using either a laryngeal mask or a Guedel airway and face mask. Success was defined as the production of two successive tidal volumes exceeding 800 ml within 40 s. The failure rate was significantly greater using the laryngeal mask compared with the face mask (P < 0.05) ...

متن کامل

The use of fiberoptic endoscopy in anesthesia.

The fiberoptic bronchoscope has contributed greatly to the practice of anesthesiology over the past 30 years. It has become an indispensable tool in the approach to the difficult airway, as well as the placement and positioning of double-lumen tubes for thoracic surgery. The equipment, preparation, and methods for using the endoscope in anesthesia, are presented here.

متن کامل

Transmission of Salmonella typhi by fiberoptic endoscopy.

In both the Tromso and the Wairoa studies, therefore, there is a strong presumption that the lipoproteins in the plasma at the time of analysis were not those present when blood• was drawn. In the Tromso study, specimens from both patients and controls had been frozen, but we still cannot be sure that the differences observed accurately reflect, either quantitatively or qualitatively, any diffe...

متن کامل

Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

BACKGROUND The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. METHODS Albuterol (2.5 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Japan Society for Clinical Anesthesia

سال: 2022

ISSN: ['0285-4945', '1349-9149']

DOI: https://doi.org/10.2199/jjsca.42.563