Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
نویسندگان
چکیده
Abstract To evaluate the repeatability and agreement of corneal biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) a partial interferometry-based device. This is cross-sectional study. Forty-eight eyes 48 patients had three consecutive for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) IOLMaster500 (Carl Zeiss Meditec, USA) on same visit. Mean keratometry (Km), central thickness (CCT), anterior chamber depth (ACD) axial length (AL) were recorded. Corneal astigmatic converted into vector components—J0 J45. Intra-device agreements amongst devices evaluated using coefficients (RCs) Bland–Altman plots, respectively. All demonstrated comparable Km (p ≥ 0.138). lowest RC J0 ≤ 0.039). Systematic difference was found compared to either SSOCTs 0.010). The ACD AL measured by showed higher < 0.002). in CCT between 0.001), mean 1.6 µm, 0.022 mm 0.021 mm, Both smaller test–retest variability measuring IOLMaster500. There significant disagreement PCI-based device; their should not be considered as interchangeable.
منابع مشابه
Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
The aim of this study was to investigate changes in the anterior segment of the eye after cycloplegia. A biometer combined with swept-source optical coherence tomography (SSOCT) was used for measurements. Patients with strabismus or amblyopia who underwent cycloplegia were included. The axial length, central corneal thickness, anterior chamber depth, and lens thickness were measured with the bi...
متن کاملMaster/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography.
In this paper, we demonstrate that the master slave (MS) interferometry method can significantly simplify the practice of coherence revival swept source optical coherence tomography (OCT) technique. Previous implementations of the coherence revival technique required considerable resources on dispersion compensation and data resampling. The total tolerance of the MS method to nonlinear tuning, ...
متن کاملNovel perspectives on swept-source optical coherence tomography
Technologies for multimodal digital imaging of vitreoretinal diseases have improved the accuracy of diagnosis and the depth of the knowledge of the mechanisms of disease and their response to treatments. Optic coherence tomography (OCT) has become a mandatory tool for the management and for the follow-up of retinal pathologies. OCT technology evolved in the last two decades from time-domain to ...
متن کاملتکرارپذیری و میزان تشابه اندازهگیریهای بیومتری توسط دستگاه swept source optical coherence (OA2000) و partial coherence interferometry (IOL Master) به عنوان مرجع
هدف: بررسی تکرارپذیری و میزان تشابه اندازهگیری پارامترهای ضخامت لنز (Lens Thickness, LT)، عمق اتاق قدامی (Anterior Chamber Depth, ACD)، طول محوری (Axial Length, AL) و کراتومتری (Keratometry, K) توسط دستگاه جدید ۲۰۰۰OA- و مقایسه آن با دستگاه ۵۰۰IOL Master. روش پژوهش: در این مطالعه مقطعی، بیماران دارای کاتاراکت در یک یا دو چشم برای ورود به مطالعه انتخاب شدند. پارامترهایAL, ACD, LT, K توسط دستگاه...
متن کاملSubgingival calculus imaging based on swept-source optical coherence tomography.
We characterized and imaged dental calculus using swept-source optical coherence tomography (SS-OCT). The refractive indices of enamel, dentin, cementum, and calculus were measured as 1.625 ± 0.024, 1.534 ± 0.029, 1.570 ± 0.021, and 2.097 ± 0.094, respectively. Dental calculus leads strong scattering properties, and thus, the region can be identified from enamel with SS-OCT imaging. An extracte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2021
ISSN: ['2045-2322']
DOI: https://doi.org/10.1038/s41598-021-93999-8