Comparison of three surgical methods in the treatment of intraarticular comminuted distal radius fractures: Volar locking plate, non-bridging external fixator, and bridging external fixator

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-articular Fractures of Distal Radius; Outcome of Treated with Bridging (static) External Fixator

..Objective: To assess the radiological and functional outcome of external fixator in the treatment of intar-articular fractures of distal radius. Study design: Descriptive case series. Place and duration of study: Orthopaedic unit District Headquarter Hospital Temargarha Lower Dir from March 2013 to March 2014. Material and methods: Twenty five patients of intra-articular fracture distal radiu...

متن کامل

Are intra-articular distal radius fractures best managed with volar locking plates or bridging external fixation?

Introduction Distal radius fractures are the sixth most commonly occurring fracture. Controversy surrounds the optimal method of fixation with both volar locking plate and bridging external fixation being advocated. This systematic review aims to compare these techniques in the treatment of intra-articular fractures. Materials and methods The electronic databases Medline and EMBASE were searche...

متن کامل

Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.

PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...

متن کامل

Treatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate - functional and radiological outcome in a prospective case-controlled series.

INTRODUCTION Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. AIMS To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate co...

متن کامل

Fixation of extra articular distal radial fractures with non bridging external fixator.

Severely comminuted fractures of distal radius often lead to impairment of wrist function. A prospective study was performed on 30 patients aged between 35-65 years of extra-articular fractures of distal radius. All patients were treated with closed manipulation of the fracture an application of non-bridging (radio radial) external fixator under radiological control. At six months after the inj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Joint Diseases and Related Surgery

سال: 2019

ISSN: 1305-8282,1309-0313

DOI: 10.5606/ehc.2019.66955