COMPARISON OF THE USE OF THE LARYNGEAL MASK AND FACE MASK BY INEXPERIENCED PERSONNEL
نویسندگان
چکیده
منابع مشابه
Comparison of the use of the laryngeal mask and face mask by inexperienced personnel.
Ten junior doctors with no postgraduate anaesthetic experience attempted to ventilate the lungs of 50 anaesthetized patients, using either a laryngeal mask or a Guedel airway and face mask. Success was defined as the production of two successive tidal volumes exceeding 800 ml within 40 s. The failure rate was significantly greater using the laryngeal mask compared with the face mask (P < 0.05) ...
متن کاملComparison of laryngeal mask and intubating laryngeal mask insertion by the naïve intubator.
Seventy-five inexperienced participants were timed inserting the laryngeal mask airway (LMA) and the intubating laryngeal mask (ILM) in one of five cadavers. Adequacy of ventilation was assessed on a three-point scale depending on chest expansion and air leak. Participants were also asked to intubate the trachea via the ILM. The ILM was inserted faster than the LMA (P < 0.05) with a greater pro...
متن کاملComparison of the Laryngeal Mask Airways: Laryngeal Mask Airway-classic and Laryngeal Mask Airway-proseal in Children
Introduction In the past 25 years with the development of various supraglottic airway devices, the armamentarium for airway management has increased. In our study, the laryngeal mask airway (LMA)-ProSeal is compared with the LMA-Classic with respect to as follows: (a) Ease of insertion and number of insertion attempts, (b) Device positional stability and possible oropharyngeal leak, (c) Airway ...
متن کاملComparison of the standard laryngeal mask airway and the ProSeal laryngeal mask airway in obese patients.
BACKGROUND The ProSeal laryngeal mask airway (PLMA) may have advantages over the laryngeal mask airway (LMA) in obese patients. We tested this hypothesis in a clinical setting. METHODS Sixty obese patients (BMI >30) were randomized to receive mechanical ventilation (tidal volume 7 ml kg(-1), PEEP 10 cm H(2)O), through either the PLMA or the LMA. A gastric tube was used in all patients. Cuff p...
متن کاملPositive pressure ventilation during fibreoptic intubation: comparison of the laryngeal mask airway, intubating laryngeal mask and endoscopy mask techniques.
BACKGROUND The efficacy of delivery of mechanical ventilation through different airway devices during fibreoptic intubation is not known. METHODS We compared the laryngeal mask airway (LMA), intubating laryngeal mask (ILM) and endoscopy mask for positive pressure ventilation (PPV) during fibreoptic intubation. In 80 adult paralysed patients, fibreoptic intubation was performed during PPV usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 1992
ISSN: 0007-0912
DOI: 10.1093/bja/69.3.320