Comparison of the Hybrid Locking Plate, Standard Dynamic Compression Plate, and Standard Dynamic Compression Plate Augmented with Bone Cement for Fixation of Osteoporotic Humeral Shaft Fractures: A Cadaveric Biomechanical Study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Plate fixation of clavicle fractures: a comparative study between Reconstruction Plate and Dynamic Compression Plate.

This study aimed at comparing the results of clavicular fracture fixation with AO Reconstruction (Recon) plate and Dynamic Compression Plate (DCP). The case notes of 39 patients with 40 acute and chronic clavicular fractures were retrospectively reviewed. The indications for fixation for acute cases comprised open fractures, the presence of sufficient skin tenting to risk skin integrity, neurov...

متن کامل

Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

متن کامل

Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.

OBJECTIVES The purpose of this study was to compare the biomechanical properties of posterolateral antiglide plating and lateral locked plating for fixation of displaced short oblique fractures of the fibula in osteoporotic bone. METHODS Short oblique fractures of the distal fibula at the level of the syndesmosis were simulated with a fibular osteotomy and ligamentous sectioning in 18 paired ...

متن کامل

fixation of intertrochanteric fractures: dynamic hip screw versus locking compression plate

conclusions despite the complications of fixation with the dhs device, it remains the most successful for treatment of intertrochanteric fractures. background according to the existing literature, the dynamic hip screw (dhs) is the preferred standard for the treatment of intertrochanteric fractures. however, some surgeons use other devices such as the locking compression plate (lcp). objectives...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Medica Philippina

سال: 2012

ISSN: 2094-9278,0001-6071

DOI: 10.47895/amp.v46i2.2155