Comparison of stress patterns and displacement in conventional cantilever fixed partial denture with resin bonded cantilever fixed partial denture: A finite element analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of conventional cantilever and resin bonded cantilever fixed partial dentures: a comparative study.

INTRODUCTION Ever since the introduction of the minimal preparation fixed partial dentures, the major concern of the clinicians has been its longevity. AIMS AND OBJECTIVE The objective of the present study was to compare the clinical performance of resin bonded cantilever bridges with conventional cantilever bridges for a period of 1 year and to evaluate the periodontal changes of abutment te...

متن کامل

evaluation of tissues surrounding implant supported fixed partial denture with and without cantilever extension

objective: the aim of this study was to evaluate and compare the status of supporting tissue around implant-supported fixed partial denture with or without cantilever clinically and radiographically during a four-year period. materials and methods: one hundred and fifty nine patients who were treated by 482 implants supported fixed partial prosthesis with and without cantilever after at least f...

متن کامل

Three-Dimensional Finite Element Analysis of Anterior Two-Unit Cantilever Resin-Bonded Fixed Dental Prostheses

The aim of this study was to evaluate the influence of different framework materials on biomechanical behaviour of anterior two-unit cantilever resin-bonded fixed dental prostheses (RBFDPs). A three-dimensional finite element model of a two-unit cantilever RBFDP replacing a maxillary lateral incisor was created. Five framework materials were evaluated: direct fibre-reinforced composite (FRC-Z25...

متن کامل

Longevity of a maxillary 2-unit cantilever fixed partial denture: clinical report.

In this clinical report, we discuss the length of service and subsequent replacement of a maxillary anterior 2-unit cantilever fixed partial denture (FPD). The FPD provided 53 years of service to the patient and was finally replaced with a 2-unit porcelain-fused-to-metal (PFM) FPD. The original prosthesis replaced a missing maxillary lateral incisor using a partial coverage metal retainer, wher...

متن کامل

Bonded Orthodontic Retainer and Fixed Partial Denture Made with Fiber Reinforced Composite Resin

Retention is the phase of orthodontic treatment which maintains teeth in their orthodontically corrected positions, following the cessation of active orthodontic tooth movement. Development of resin-impregnated, fiber-reinforced composite materials has provided the potential to develop new approaches for stabilizing teeth and replacing teeth conservatively. This case report describes the rehabi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Dental Research

سال: 2010

ISSN: 0970-9290

DOI: 10.4103/0970-9290.62797