Comparison of Routine Brain Imaging at 3 T and 7 T
نویسندگان
چکیده
منابع مشابه
Comparison of Routine Brain Imaging at 3 T and 7 T.
OBJECTIVE The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating disease, gliomas, cerebrovascular disease, and epilepsy, with comparable sequenc...
متن کاملQuantitative magnetization transfer imaging of human brain at 7 T
Quantitative magnetization transfer (qMT) imaging yields indices describing the interactions between free water protons and immobile macromolecular protons. These indices include the macromolecular to free pool size ratio (PSR), which has been shown to be correlated with myelin content in white matter. Because of the long scan times required for whole-brain imaging (≈20-30 min), qMT studies of ...
متن کاملClinical vascular imaging in the brain at 7 T☆
Stroke and related cerebrovascular diseases are a major cause of mortality and disability. Even at standard-field-strengths (1.5T), MRI is by far the most sensitive imaging technique to detect acute brain infarctions and to characterize incidental cerebrovascular lesions, such as white matter hyperintensities, lacunes and microbleeds. Arterial time-of-flight (TOF) MR angiography (MRA) can depic...
متن کاملComparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters.
Previous studies have shown that under some conditions, noise fluctuations in an fMRI time-course are dominated by physiological modulations of the image intensity with secondary contributions from thermal image noise and that these two sources scale differently with signal intensity, susceptibility weighting (TE) and field strength. The SNR of the fMRI time-course was found to be near its asym...
متن کاملFeasibility of magnetic resonance redox imaging at low magnetic field: comparison at 1 T and 7 T.
The effect of different static magnetic field strengths, 1 T or 7 T, on the quality of nitroxyl radical-based magnetic resonance redox imaging (MRRI) was examined. A stable nitroxyl radical, 3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (MC-PROXYL), was used as a T1 contrast agent. Phantoms and animals were scanned at 1 T and 7 T using a similar gradient echo sequence. The quality of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Investigative Radiology
سال: 2016
ISSN: 1536-0210,0020-9996
DOI: 10.1097/rli.0000000000000256