Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment.

BACKGROUND Although intravascular ultrasound (IVUS) is the present standard for the evaluation of optimum stent deployment, this technique is expensive and not routinely feasible in most catheterization laboratories. Coronary pressure-derived myocardial fractional flow reserve (FFRmyo) is an easy, cheap, and rapidly obtainable index that is specific for the conductance of the epicardial coronar...

متن کامل

Comparison of intravascular ultrasound and quantitative coronary angiography for the assessment of coronary artery disease progression.

BACKGROUND The relative merits of quantitative coronary analysis (QCA) and intravascular ultrasound (IVUS) for the assessment of progression/regression in coronary artery disease are uncertain. To explore this subject further, we analyzed the angiographic and IVUS data derived from a contemporary clinical trial population. METHODS AND RESULTS We investigated the relationships between QCA and ...

متن کامل

Mechanisms of residual lumen stenosis after high-pressure stent implantation: a quantitative coronary angiography and intravascular ultrasound study.

BACKGROUND Intravascular ultrasound (IVUS) studies have demonstrated that stents are frequently suboptimally expanded despite the use of high pressures for deployment. The purpose of this study was to identify the mechanisms responsible for such residual lumen stenosis. METHODS AND RESULTS Fifty-seven lesions from 50 patients treated with high-pressure (median+/-interquartile range, 14+/-2 at...

متن کامل

Sirolimus-eluting stent for the treatment of in-stent restenosis: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY ...

متن کامل

Intravascular ultrasound to assess left main stem coronary artery lesion.

A man of 70 underwent coronary arteriography for the assessment of angina. The appearance of the left coronary main stem was slightly abnormal but no definite stenosis could be delineated. Intracoronary ultrasound examination with a 4.8 French intravascular ultrasound probe showed an extensive plaque in the distal left main stem and proximal left anterior descending coronary artery, with a shel...