Comparison of Pre and Post LASIK Corneal Thickness by Orbscan, Anterior Segment Optical Coherence Tomography, Specular Microscopy, Ultrasonic Pachymetry
نویسندگان
چکیده
منابع مشابه
Comparison of central corneal thickness measured with anterior segment optical coherence tomography versus ultrasonic pachymetry.
PURPOSE To compare central corneal thickness measured with anterior segment optical coherence tomography (AS-OCT) and ultrasonic pachymetry (UP). METHOD A prospective, observational and cross-sectional study was performed. The central corneal thickness was measured in 112 eyes of 112 consecutive patients with AS-OCT and UP. All examinations were performed by the same examiner. The measurement...
متن کاملComparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan
BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...
متن کاملComparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis.
AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...
متن کاملSCIENTIFIC REPORT Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...
متن کاملMeasurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
BACKGROUND To compare corneal epithelial thickness (CET) and limbal epithelial thickness (LET) measured by anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscope (IVCM) in normal subjects, and evaluate the consistency between them. METHODS Thirty-eight normal subjects (17 men and 21 women) were enrolled in this study. AS-OCT was performed at central cornea and ...