Comparison of Oxygen Saturation and Heart Rate (HR) Measurements from Masimo and Nellcor Pulse Oximeters in Newly Born Infants
نویسندگان
چکیده
منابع مشابه
Comparison of heart rate and oxygen saturation measurements from Masimo and Nellcor pulse oximeters in newly born term infants.
AIM To compare heart rate (HR) measurements from Masimo and Nellcor pulse oximeters (POs) against HR measured via a three lead electrocardiograph (ECG) (HRECG ). We also compared peripheral oxygen saturation (SpO2 ) measurements between Nellcor and Masimo oximeters. METHOD Term infants born via elective caesarean section were studied. ECG leads were placed on the infant's chest and abdomen. M...
متن کاملPerformance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
This crossover observational study compares the data characteristics and performance of new-generation Nellcor OXIMAX and Masimo SET SmartPod pulse oximeter technologies. The study was conducted independent of either original equipment manufacturer (OEM) across eleven preterm infants in a Neonatal Intensive Care Unit (NICU). The SmartPods were integrated with Dräger Infinity Delta monitors. The...
متن کاملMotion resistant pulse oximetry in neonates.
BACKGROUND Pulse oximetry is widely used in neonates. However, its reliability is often affected by motion artefact. Clinicians confronted with questionable oxygen saturation (SpO(2)) values often estimate the reliability by correlating heart rate (HR) obtained with the oximeter with that obtained by electrocardiogram. OBJECTIVE To compare the effects of motion on SpO(2) and HR measurements m...
متن کاملEffects of position on oxygen saturation and heart rate in very low birth weight neonates
Background: Desirable oxygenation of preterm newborns has particular importance, for this reason different methods have been proposed to improve oxygenation of the newborns; one of these methods is the newborns' position. The aim of this study was to determine the effect of the position of low birth weight neonates on arterial oxygen saturation and heart rate. Methods: This interventional st...
متن کاملComparison of two new generation pulse oximeters with arterial oxygen saturation in critically ill children.
OBJECTIVES To compare the performance of two new generation pulse oximeters, one with enhanced signal extraction technology (SET) and other without enhanced SET in detecting hypoxemia and to correlate it with arterial blood gas analysis. METHODS Forty-eight patients, admitted to pediatric intensive care unit (PICU) of a teritiary care teaching hospital in India for critical care and support d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pediatric Research
سال: 2011
ISSN: 0031-3998,1530-0447
DOI: 10.1038/pr.2011.354