Comparison of MPC and PI Controller for Grid-Connected Cascade Inverter

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Grid-Connected Solar Micro-inverter Based on Fuzzy PI Controller

Grid-connected solar micro-inverter is a highly nonlinear and time-varying system, so it is difficult to achieve good control effect using traditional PI controller. In this paper, small signal analysis model of micro-inverter is established, grid-connected current control strategy composed of fuzzy PI controller and grid voltage feed-forward is put forward, and the initial parameters of PI con...

متن کامل

Photovoltaic Grid – connected Inverter Based MPPT Using PI Regulator

In this paper, an improved maximum power point (MPP) tracking (MPPT) with better performance based on voltage-oriented control (VOC) is proposed to solve a fastchanging irradiation problem. In VOC, a cascaded control structure with an outer dc link voltage control loop and an inner current control loop is used. The currents are controlled in a synchronous orthogonal d, q frame using a decoupled...

متن کامل

Optimization of the Lyapunov Based Nonlinear Controller Parameters in a Single-Phase Grid-Connected Inverter

In this paper, optimization of the backstepping controller parameters in a grid-connected single-phase inverter is studied using Imperialist competitive algorithm (ICA), Genetic Algorithm (GA) and Particle swarm optimization (PSO) algorithm. The controller is developed for the system based on state-space averaged model. By selection of a suitable Lyapunov function, stability of the proposed con...

متن کامل

Comparative Study Between PI and Resonant Controllers for PV Grid-Connected Inverter

Control of PV-grid connected inverter introduces a delay between sinusoidal current reference and measured current at the output of the inverter. This leads to a phase difference between the current injected by the inverter and grid voltage when using a simple PI controller. To overcome this problem, PI controllers used to control injected currents to the grid have been substituted, in this stu...

متن کامل

The Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter

Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Elektronika ir Elektrotechnika

سال: 2014

ISSN: 2029-5731,1392-1215

DOI: 10.5755/j01.eee.20.6.7266