Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy
PURPOSE To evaluate the accuracy of the optical coherence tomography-based (OCT formula) and Barrett True K (True K) intraocular lens (IOL) calculation formulas in eyes with previous radial keratotomy (RK). METHODS In 95 eyes of 65 patients, using the actual refraction following cataract surgery as target refraction, the predicted IOL power for each method was calculated. The IOL prediction e...
متن کاملComparison of IOL power calculation methods and intraoperative wavefront aberrometer in eyes after refractive surgery.
PURPOSE To compare preoperative methods for calculating intraocular lens (IOL) power versus the intraoperative wavefront aberrometer in eyes with a history of refractive surgery. METHODS A retrospective study of 46 eyes (33 patients) with previous refractive surgery that underwent subsequent cataract surgery was conducted. Suggested IOL power predicted by ORange intraoperative wavefront aberr...
متن کاملToric Iol Power Calculation
Obviously, toric lenses have to remain in stable positions after implantation bearing in mind that for every 10 degrees of misalignment, there is one third loss of toric correction. While some time ago this was still a problem, toric IOLs of today are significantly less affected by lens rotation. Another disturbing issue with toric lenses has also been fixed in the meantime: according to a new ...
متن کاملComparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.
Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...
متن کاملComparison of Intraoperative Aberrometry, OCT-Based IOL Formula, Haigis-L, and Masket Formulae for IOL Power Calculation after Laser Vision Correction.
PURPOSE To compare the accuracy of intraoperative aberrometry technology and the Fourier-domain optical coherence tomography (OCT)-based intraocular lens (IOL) formula for IOL power calculation in eyes undergoing cataract surgery after previous laser vision correction (LVC) compared with established methods. DESIGN Retrospective consecutive case series. PARTICIPANTS Patients undergoing cata...