Comparison of intraocular pressure measurement with Schiotz tonometer and Tono-Pen Vet tonometer in healthy dogs

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...

متن کامل

comparison of intraocular pressure measurement with the noncontact pulsair 3000 tonometer and goldmann applanation tonometer

purpose: to compare intraocular pressure (iop) measurement with pulsair non-contact tonometer and goldmann applanation tonometer (gat). methods: in this cross-sectional study, during a complete ophthalmologic examination, each patient underwent pulsair tonometry three times at 5 minutes intervals and then goldmann tonometry at the same intervals. mean iop values were measured and analyzed. resu...

متن کامل

Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL

OBJECTIVE WE AIMED TO COMPARE INTRAOCULAR PRESSURE (IOP) MEASUREMENTS VIA THREE DIFFERENT TONOMETERS: the Goldmann applanation tonometer (GAT), the Tono-Pen(®) XL (TPXL), and a non-contact airpuff tonometer (NCT). METHODS This was a cross-sectional study of 200 eyes from 200 patients. Right eyes of all patients were included in this study. IOP was measured via GAT, NCT, and TPXL by three phys...

متن کامل

measurement of intraocular pressure using schiotz vs tono-pen tonometers in patients with primary congenital glaucoma

purpose: to compare the tono-pen and schiotz tonometers in measurement of intraocular pressure (iop) in patients with primary congenital glaucoma. methods: this study was conducted on 38 eyes of 20 patients with primary congenital glaucoma. all measurements were performed under general anesthesia. one minute after receiving halothane 3% iop was determined by tono-pen and then by schiotz tonomet...

متن کامل

Noninvasive measurement of rodent intraocular pressure with a rebound tonometer.

PURPOSE The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in consc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Veterinary Research

سال: 2018

ISSN: 2450-8608

DOI: 10.2478/jvetres-2018-0018