Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis
نویسندگان
چکیده
منابع مشابه
comparison of intraocular pressure measurements by the ocular response analyzer and goldmann applanation tonometer after penetrating keratoplasty in keratoconic patients
purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 kera...
متن کاملComparison of Intraocular Pressure Fluctuations Measured by Goldmann Applanation Tonometer and Pulsatile Ocular Blood Flow Analyser
BACKGROUND Intraocular pressure (IOP) is the major known risk factor in glaucoma and the primer mover of the functional damage in glaucomatous patients but it is not a unique determinant of glaucomatous damage. Clinical assessment of glaucoma patients may not be a true reflection of overall IOP control. Evaluation of the effect of glaucoma medication is restricted by measurement of IOP as a dyn...
متن کاملintraocular pressure measurements after penetrating keratoplasty using the ocular response analyzer versus goldmann applanation tonometer
purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 kerat...
متن کاملComparison of the ocular response analyzer and the Goldmann applanation tonometer for measuring intraocular pressure after deep anterior lamellar keratoplasty.
PURPOSE To compare intraocular pressure (IOP) measured using the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) with that measured using the Goldmann applanation tonometer (GAT) in keratoconic eyes after deep anterior lamellar keratoplasty (DALK) and evaluate the influence of central graft thickness (CGT), corneal astigmatism, corneal hysteresis (CH), and corneal r...
متن کاملComparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in glaucoma
Purpose. To compare the intraocular pressure (IOP) readings taken by ICare, Pascal dynamic contour tonometer (DCT), and ocular response analyzer (ORA) with those taken by Goldmann applanation tonometer (GAT). We sought to evaluate the influence of central corneal thickness (CCT) on IOP measurements and to compare patients’ preferences for the four tonometers. Methods. In this prospective study,...