Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plate

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate

Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly ...

متن کامل

Internal fixation of fractures of both bones forearm: Comparison of locked compression and limited contact dynamic compression plate

BACKGROUND The locking compression plate (LCP) with combination holes is a newer device in fracture fixation. We undertook a study comparing the LCP with limited contact dynamic compression plate (LC-DCP) in the treatment of diaphyseal fractures of both bones of the forearm. MATERIALS AND METHODS This is a prospective comparative study, 36 patients (18 in each group) with fractures of both th...

متن کامل

Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

متن کامل

Stabilisation of diaphyseal fractures of both bones forearm with limited contact dynamic compression or locked compression plate: comparison of clinical outcomes

3 To acquire adequate range of pronation and supination, reclamation of length, apposition, axial and rotational alignment is paramount. Deforming muscular forces make union complexities more plausible. 4 Although open reduction and internal fixation with plate is commonly accustomed as a treatment of choice, the most efficacious implant remains unsettled. 5 Through ages, compression has been a...

متن کامل

Biomechanical analysis of limited-contact plate used for osteosynthesis.

This paper presents the results of numerical analysis aimed at determining the state of stresses and displacements of compression plate used in osteosynthesis of tibia, carried out by applying finite element method using the ANSYS program. The analysis took into account two variants of the osteosynthesis. Variant I included the osteosynthesis in which plate was attached directly to the bone, in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Orthopaedics

سال: 2009

ISSN: 0341-2695,1432-5195