Comparison of impression techniques and double pouring by dental cast’s accuracy
نویسندگان
چکیده
منابع مشابه
Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring
This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-spe...
متن کاملAccuracy of stone casts obtained by different impression materials.
Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full cro...
متن کاملeffect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts
background: different factors such as impression techniques and materials can affect the passive fi t between the superstructure and implant. the aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts. materials and methods: four internal hex implants (biohorizons ø4 mm) were placed on a metal maxil...
متن کاملThree-dimensional accuracy of different impression techniques for dental implants
BACKGROUND Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. MATERIALS AND METHODS Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BI...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Brazilian Journal of Oral Sciences
سال: 2019
ISSN: 1677-3225