Comparison of hematological parameters among newborns with meconium stained amniotic fluid and clear amniotic fluid
نویسندگان
چکیده
منابع مشابه
The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid
Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...
متن کاملIntralipid treatment for newborns with meconium stained amniotic fluid (MSAF)
This study (1) included one hundred and forty-one vigorous babies born through meconium stained amniotic fluid, of which 36.9% (52) babies developed respiratory distress. Of the 52 babies who developed respiratory distress 19.23%(10 babies) developed meconium aspiration syndrome (MAS). In this study, it was observed factors like caesarean section and thick meconium increased risk of respiratory...
متن کاملComparison of Neonatal Outcome with Meconium-Stained Amniotic Fluid in Normal Vaginal Delivery and Cesarean Section
Background and Objectives: Given the consequences and serious dangers, which threatens neonates born with meconium-stained amniotic fluid, and also due to the high prevalence of cesarean section, the present research was carried out with the aim of comparing the outcomes of neonates with meconium - stained amniotic fluid in vaginal delivery and cesarean section. Methods: The present study wa...
متن کاملStudy of prognostic factors for meconium-stained amniotic fluid
Introduction: meconium is the thick, Green - Black, with a bad odor material, that founded around the third month of pregnancy in the intestines of fetus. 8 to 15 percent of infants has the evidence of meconium stained fluid at birth. In this study the factors affecting maternal and neonatal meconium-stained amniotic fluid be examined. Methods: This study was done in the Vali-e- asr hospital ...
متن کاملIntrapartum amnioinfusion for meconium-stained amniotic fluid
Aim: The purpose of this study was to assess whether the intrapartum amnioinfusion (AI) in the presence of meconium-stained amniotic fluid (MSAF) influence the rate of cesarean section and perinatal outcome. Material and methods: The investigated group consisted of 405 pregnant women in labor with meconium-stained amniotic fluid: 163 had performed AI, and 242 constituted a control group (withou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Contemporary Pediatrics
سال: 2019
ISSN: 2349-3291,2349-3283
DOI: 10.18203/2349-3291.ijcp20194720