Comparison of Gradient Echo and Multi shot Echo Planar Imaging in Functional MRI
نویسندگان
چکیده
منابع مشابه
Perfusion-sensitive MR imaging of gliomas: comparison between gradient-echo and spin-echo echo-planar imaging techniques.
BACKGROUND AND PURPOSE The different sensitivities to vessel size of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI) might indicate the relative cerebral blood volumes (rCBVs) of different tumor sizes. The techniques of GE-EPI and SE-EPI were compared for detecting low- versus high-grade gliomas. METHODS Six patients with low-grade gliomas and 19 patients with high-grade...
متن کاملQuiet echo planar imaging for functional and diffusion MRI
PURPOSE To develop a purpose-built quiet echo planar imaging capability for fetal functional and diffusion scans, for which acoustic considerations often compromise efficiency and resolution as well as angular/temporal coverage. METHODS The gradient waveforms in multiband-accelerated single-shot echo planar imaging sequences have been redesigned to minimize spectral content. This includes a s...
متن کاملActivation of the sensorimotor cortex at 1.0 T: comparison of echo-planar and gradient-echo imaging.
PURPOSE The increasing demand for the clinical application of functional MR imaging raises the question of whether this technique can be routinely performed on 1.0-T MR scanners. To this end, we assessed the feasibility of functional MR imaging at 1.0 T. METHODS Healthy volunteers were scanned during the performance of a motor task. Functional data were acquired with echo-planar imaging (EPI)...
متن کاملFunctional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI).
Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination...
متن کاملImproving diffusion MRI using simultaneous multi-slice echo planar imaging
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1996
ISSN: 0369-4305,1881-4883