Comparison of gallium scan, computed tomography, and magnetic resonance in patients with mediastinal Hodgkin's disease
نویسندگان
چکیده
منابع مشابه
Comparison of gallium scan, computed tomography, and magnetic resonance in patients with mediastinal Hodgkin's disease.
BACKGROUND In patients with Hodgkin's disease, the use of gallium-67 scintigraphy (Ga-67) compared to conventional staging and restaging techniques is still controversial. In particular, in a combined modality treatment with chemotherapy and radiotherapy given in sequence, its role in detecting active disease after chemotherapy may be useful in planning the subsequent radiotherapeutic strategy....
متن کاملBimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملMagnetic resonance imaging in neurologic diseases--comparison with computed tomography.
Magnetic resonance (MR) and computed tomography (CT) imagings were compared in 121 patients with various neurologic diseases. MR was performed with either 0.15 Tesla resistive or 2.0 Tesla superconducting systems developed by Korea Advanced Institute of Science and Technology (KAIST), using multi-slice spin echo technique with a variety of pulse sequences reflecting proton density, T1 and T2 re...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Oncology
سال: 1997
ISSN: 0923-7534
DOI: 10.1093/annonc/8.suppl_1.s53