Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis

PURPOSE The aim of this study is to compare the dosimetric differences between four techniques for spine stereotactic body radiotherapy (SBRT): CyberKnife (CK), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) with dynamic jaws (HT-D) and fixed jaws (HT-F). MATERIALS/METHODS Data from 10 patients were utilized. All patients were planned for 24 Gy in two fractions, with th...

متن کامل

Dosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer

PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...

متن کامل

Dosimetric Comparison of Two Craniospinal Radiotherapy Techniques for Treatment Optimization

Introduction: Orthogonal radial fields are those in which the central axes are perpendicular to each other. An example of these orthogonal fields is the set of craniospinal orthogonal fields that are used for radiotherapy of medulloblastoma. Craniospinal radial fields consist of two parallel-opposed fields for brain exposure and one or two posterior spinal fields for spinal cord exposure. The m...

متن کامل

Stereotactic body radiotherapy for solitary spine metastasis

A clear consensus has not been established regarding the best treatment for solitary bone metastasis. Here, we reviewed the medical records of patients with a controlled primary malignancy who had only solitary spine metastasis without metastasis to the extraspinal bone or viscera and underwent treatment between April 2007 and December 2012 with stereotactic body radiosurgery using CyberKnife, ...

متن کامل

Dosimetric comparison of different treatment modalities for stereotactic radiotherapy

BACKGROUND The modalities for performing stereotactic radiotherapy (SRT) on the brain include the cone-based linear accelerator (linac), the flattening filter-free (FFF) volumetric modulated arc therapy (VMAT) linac, and tomotherapy. In this study, the cone-based linac, FFF-VMAT linac, and tomotherapy modalities were evaluated by measuring the differences in doses delivered during brain SRT and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2018

ISSN: 1526-9914

DOI: 10.1002/acm2.12271