Comparison of Flux-Weakening Control Strategies of Novel Hybrid-Excited Doubly Salient Synchronous Machines
نویسندگان
چکیده
منابع مشابه
Traction Permanent Magnet Synchronous Motor Torque Control with Flux Weakening
The paper deals with analysis of dynamic behavior of a feedback flux weakening control of PMSM traction drive for light vehicles. The PMSM flux weakening is very important for traction drives. Two torque control structures were analyzed pure feedback control and feedback control with prediction of the field producing current component. The principles, control structures, simulation and experime...
متن کاملThe Vector Control of Three-Phase Salient Pole Synchronous Machines Supplied by Pulse-Width- Modulated Voltage Source Inverters
In this paper, computer simulation of a three-phase synchronous motor drive is described. This drive/system is supplied with a new type of pulse-width modulated voltage source inverter (PWM VSI) whose amplitude of the first harmonic, compared to a conventional sinusoidal PWM VSI, is increased by about 17% and whose amplitude of higher harmonics is also reduced inversely proportional to their or...
متن کاملThe Vector Control of Three-Phase Salient Pole Synchronous Machines Supplied by Pulse-Width- Modulated Voltage Source Inverters
In this paper, computer simulation of a three-phase synchronous motor drive is described. This drive/system is supplied with a new type of pulse-width modulated voltage source inverter (PWM VSI) whose amplitude of the first harmonic, compared to a conventional sinusoidal PWM VSI, is increased by about 17% and whose amplitude of higher harmonics is also reduced inversely proportional to their or...
متن کاملA Review on Modelling of the Maximum Lagging Current Test Method of Salient Pole Synchronous Machines
Quadrature-axis reactance for various reasons comes into account as one of the most important parameters of salient pole synchronous machine. There are several common standard methods for measuring this parameter that also have been explained with some details in the standards, scientific papers and text books. One of these methods is the maximum lagging current test that is done simply at no-l...
متن کاملDynamic Motor Parameter Identification for High Speed Flux Weakening Operation of Brushless Permanent Magnet Synchronous Machines
An experimental investigation is conducted to determine the behaviour of brushless PM synchronous machine parameters in the high speed flux weakening operating range. Real-time operating characteristics are determined for two commercially available 4 N·m interior PM synchronous machines. Special computer assisted measuring techniques are employed using an experimental vector controlled drive, c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Industry Applications
سال: 2019
ISSN: 0093-9994,1939-9367
DOI: 10.1109/tia.2019.2909494