Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.

We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...

متن کامل

Evaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.

Sixty-seven digoxin-containing sera were analyzed by both radioimmunoassay and EMIT. After some important modifications of the EMIT method, agreement between the two methods was very good. Reproducibility of the EMIT assay was excellent; daily variations in values found for control sera were quite small, and recovery of added digoxin was good. Slight hemolysis hadnegligible effects, but highly ...

متن کامل

Evaluation of fluorescence polarization immunoassay for serum thyroxine determination.

We have evaluated a fluorescence polarization immunoassay for thyroxine (T4) using the polarization analyzer IBF-129. Fluorescence polarization could be measured within 20 to 23 seconds after addition of fluorescein labeled thyroxine. The method exhibited excellent specificity and acceptable accuracy. The average intra- and inter-assay coefficients of variation were 4.8 and 12.3%, resepectively...

متن کامل

Comparison of fluorescence polarization immunoassay and enzyme immunoassay for free carbamazepine in serum or plasma ultrafiltrates from epileptic patients.

CLINICAL CHEMISTRY, Vol. 30, No.8, 1984 1425 bined isoenzyme analysis using the DuPont aca analyzer to measure CKMB and LDH1. InBiologieProspective. ComptRenddu5 Colloq de Pont-d-Mou8son, MM Galteau, G Sleet, J Henny, Eds., Masson, Paris, 1983, pp 627-630. 8. McCoy MT. Aguanno JJ, Ritzms nn SE. Lactate dehydrogenase isoenzyme 1. A rapid assay for ischemic myocardial disease. Arch Intern Med 143...

متن کامل

Enzyme immunoassay for gentamicin.

We describe a gentamicin assay in which a peroxidase-gentamicin conjugate competes with gentamicin for binding to a gentamicin antibody adsorbed to a polystyrene solid phase. The assay can be completed in 30 min and requires 50 microliter of diluted serum. The precision and accuracy are equivalent to that of a radioimmunoassay technique and the reagents are stable for several months.