COMPARISON OF ENERGY DOSES 10 MV DISTRIBUTION USING PERCENTAGE DEPTH DOSE (PDD) METHOD ON LINAC: ELECTA AND SIEMENS
نویسندگان
چکیده
منابع مشابه
Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging
Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...
متن کاملMonte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
متن کاملCalculating Weighting Factors for Mixing Megavoltage Photon Beams to Achieve Desirable Dose Distribution in Radiotherapy
Background: In radiotherapy, low-energy photon beams are better adapted to the treated volume, and the use of high-energy beams can reduce hot spots in the radiation therapy. Therefore, mixing low and high energies with different ratios can control the rate of hotspots, as well as the dose distribution of the target volume.Material and Methods: The percentage depth doses (PDDs) were calculated ...
متن کاملDetermination of Percentage Depth Dose (Pdd) of Pagat Gel Dosimeter By Electron Beams
Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...
متن کاملdetermination of primary electron beam parameters in a siemens primus linac using monte carlo simulation
the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Natural
سال: 2018
ISSN: 2541-4062,1411-8513
DOI: 10.24815/jn.v18i2.11133