Comparison of DSOGI-Based PLL for Phase Estimation in Three-Phase Weak Grids
نویسندگان
چکیده
The paper presents a summary of different double second-order generalized integrator (DSOGI)-based phase-locked loop (PLL) algorithms for synchronization with three-phase weak grids. methods are compared through simulation under variety grid conditions, such as unbalanced phase voltages, high low-order harmonics distortion, frequency steps, jumps, and voltage sags. Following the results, three that have shown overall best results an experimental setup further validation operation voltage-source converter. Based on obtained benchmark table is presented allows ranking performance tested expected conditions.
منابع مشابه
synthesis of platinum nanostructures in two phase system
چکیده پلاتین، فلزی نجیب، پایدار و گران قیمت با خاصیت کاتالیزوری زیاد است که کاربرد های صنعتی فراوانی دارد. کمپلکس های پلاتین(ii) به عنوان دارو های ضد سرطان شناخته شدند و در شیمی درمانی بیماران سرطانی کاربرد دارند. خاصیت کاتالیزوری و عملکرد گزینشی پلاتین مستقیماً به اندازه و- شکل ماده ی پلاتینی بستگی دارد. بعضی از نانو ذرات فلزی در سطح مشترک مایع- مایع سنتز شده اند، اما نانو ساختار های پلاتین ب...
Linear Three-phase State Estimation for Lv Grids Using Pseudo Measurements Based on Approximate Power Distributions
The large increase of distributed generation (DG) of photovoltaic (PV) systems in low voltage (LV) grids results in increasing voltage magnitudes and line loadings. Due to a lack of network observability in present LV grids, distribution system operators (DSOs) cannot detect and respond to any limit violations. Even with data collected by the expected rollout of smart meters, full network obser...
متن کاملPressure Loss Estimation of Three-Phase Flow in Inclined Annuli for Underbalanced Drilling Condition using Artificial Intelligence
Underbalanced drilling as multiphase flow is done in oil drilling operation in low pressure reservoir or highly depleted mature reservoir. Correct determination of the pressure loss of three phase fluids in drilling annulus is essential in determination of hydraulic horsepower requirements during drilling operations. In this paper the pressure loss of solid-gas-liquid three-phase fluids flow in...
متن کاملThree-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method
In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...
متن کاملPll for Single Phase Grid Connected Inverters
In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electricity
سال: 2021
ISSN: ['2673-4826']
DOI: https://doi.org/10.3390/electricity2030015