Comparison of DC linear and non‐linear models for multi‐terminal VSC HVDC networks
نویسندگان
چکیده
منابع مشابه
Comparison between linear and nonlinear models for surge motion of TLP
Tension-Leg Platform (TLP) is a vertically moored floating structure. The platform is permanently mooredby tendons. Surge equation of motion of TLP is highly nonlinear because of large displacement and it should be solved with perturbation parameter in time domain. This paper compare the dynamic motion responses of a TLP in regular sea waves obtained by applying three method in time domain usin...
متن کاملDesign and Analysis of Dc Voltage Control of Multi-terminal Vsc- Hvdc Systems
DESIGN AND ANALYSIS OF DC VOLTAGE CONTROL OF MULTI-TERMINAL VSCHVDC SYSTEMS G.PURUSHOTHAM, S. FAHMEEDA PARVEEN, G.VENKATA SURESH BABU PG Student, 2 Assistant Professor, Associate Professor & HOD, Department of Electrical and Electronics Engineering SITS, Kadapa, Andhra Pradesh, India. _________________________________________________________________________ ABSTRACT: This paper discusses a mult...
متن کاملDynamic Harmonic Modeling and Analysis of VSC-HVDC Systems
Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...
متن کاملVoltage Stability Bifurcation Analysis for AC / DC Systems with VSC - HVDC
and Applied Analysis 3 3. Voltage Stability Model for AC/DC Systems with VSC-HVDC 3.1. The Modified Power Flow Algorithm Based on Sequential Iteration Method. For the previous model of AC/DC system with VSC-HVDC, the simplified power flow equations are given by fac = 0, fac-dc = 0, fdc = 0, (7) where fac = [ΔPa1, ΔQa1, . . . , anAC , anAC T, fac-dc = [ΔPt1, ΔQt1, . . . , tnVSC , tnVSC ] T, fdc ...
متن کاملDC Impedance-Model-Based Resonance Analysis of a VSC-HVDC System
Resonances can have negative impact on a Voltage Source Converter-High Voltage DC (VSC-HVDC) system. This paper develops dc impedance models for the rectifier and inverter stations for a VSC-HVDC system when they are viewed from a dc terminal. The impedance models take converter controllers into account. The derived impedance models are validated by comparing frequency responses of the analytic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Engineering
سال: 2019
ISSN: 2051-3305,2051-3305
DOI: 10.1049/joe.2018.8152