Comparison of Cervical Cancer Radiation in Bladder Organs with 10 MV LINAC Energy Radiotherapy Using 3DCRT and IMRT Techniques at Sanglah Hospital Denpasar

نویسندگان

چکیده

A study has been conducted on comparative analysis of cervical cancer radiation to the bladder organ with 10 MV energy LINAC (Linear Accelerator) radiotherapy using 3DCRT (Three Dimension Conformal Radiotherapy) technique and IMRT (Intensity Modulated Radiation Therapy) at Sanglah Hospital, Denpasar. The techniques were compared by analyzing values ??of HI (Homogeneity Index), CI (Conformity Index) dose distribution in OAR (Organ At Risk), namely bladder. data used are 30 patient photon beam planning a total 5000 cGy. In calculating values, 98%, 50%, 2% target volume 95% PTV average Bladder organs. was obtained from DVH (Dose Volume Histogram) statistics contained TPS (Treatment Planning System). results value 0.0818 for 0.0899 statistical test Asimp.Sig (2-tailed) 0.056> 0.05 which means it is not significant, while 0.9500 0.9499 0.970> meanwhile percentage an result irradiation techniques, 96% 88%, respectively, results, 0.000 <0.05, significant. Cervical better than because minimizes absorbed OAR, can be seen getting smaller percentage.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: dosimetric and radiobiologic analysis

background: to analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (imrt) and 3 dimensional conformal radiotherapy (3dcrt) and selection of optimal photon energy for imrt treatments. material and methods: 24 patients with localized prostate carcinoma were planned for 3dcrt and imrt techniques. radiation dose of 54 gy with 2 gy/fraction, was planned to p...

متن کامل

Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma

Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....

متن کامل

Comparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients

Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Buletin Fisika

سال: 2022

ISSN: ['1411-4690', '2580-9733']

DOI: https://doi.org/10.24843/bf.2023.v24.i02.p05