Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary versus Venous Blood Glucose in Patients with Coma

1 Dear Sir, The recent publication on “comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma” is very interesting.[1] Yaraghi et al. concluded that “capillary blood glucose measurement by using glucometer is not recommended for patients in coma.”[1] In fact, there are many previous comparative studies betwe...

متن کامل

Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels.

The relationship between glucose concentrations in interstitial fluid (ISF) and blood has generated great interest due to its importance in minimally invasive and noninvasive techniques for measuring blood glucose. The relationship between glucose levels in dermal ISF, and capillary and venous blood was studied with the dermal ISF samples obtained using the suction blister technique. The study ...

متن کامل

comparison of blood glucose values using two glucose meters and standard laboratory method in hospitalized patients in a teaching hospital

background : diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. quality of blood glucose monitoring utilizing glucometers in iranian hospitalized patients has not been well published in the literature. we evaluated the accuracy and consistency of the results of two devices compared with the standard l...

متن کامل

Variations of blood glucose level in non-diabetic patients before and after Electroconvulsive Therapy

Introduction: Application of electroconvulsive therapy (ECT) for the induction of generalized seizure was first introduced in 1938. It is applied for disorders as severe depression particularly for cases which do not respond to drug therapy, or during pregnancy when medication is detrimental to the fetus. The debate on the effect of ECT on blood glucose level is still contradictory. However, st...

متن کامل

Capillary versus venous bedside blood glucose estimations.

OBJECTIVES To determine the mean difference and correlation between capillary and venous bedside glucose estimation in comparison to laboratory blood glucose analysis in emergency department (ED) patients. METHODS Blood glucose levels were synchronously analysed using a bedside blood glucometer on capillary and venous derived samples from consenting ED patients aged >12 years. The venous samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advanced Biomedical Research

سال: 2015

ISSN: 2277-9175

DOI: 10.4103/2277-9175.170242