Comparison of Body Fat Results from 4 Bioelectrical Impedance Analysis Devices vs. Air Displacement Plethysmography in American Adolescent Wrestlers
نویسندگان
چکیده
منابع مشابه
Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
BACKGROUND The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and w...
متن کاملComparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults.
BACKGROUND Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. OBJECTIVE The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 ot...
متن کاملA Comparison of Body Composition Across Two Phases of the Menstrual Cycle Utilizing Dual-Energy X-Ray Absorptiometry, Air Displacement Plethysmography, and Bioelectrical Impedance Analysis
The purpose of this investigation was to utilize several different technologies to compare body composition results across two phases of the menstrual cycle, and to investigate whether being on hormonal birth control or not has any effect on results. The secondary purpose was to determine if body satisfaction or perception of fluid retention differed across phases or between groups. A total of ...
متن کاملTotal body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode...
متن کاملCorrelation of Air Displacement Plethysmography with Alternative Body Fat Measurement Techniques in Men and Women
Obesity has reached epidemic proportions with serious health consequences. Techniques used to measure body fat (BF) yield variable BF estimates, and this variability may lead to underestimation or overestimation of BF and subsequent treatment options. The measurements that are most accurate (Dual-Energy X-ray Absorptiometry (DEXA) and Air Displacement Plethysmography (ADP)) are expensive and of...