Comparison of Bag-Valve-Mask Hand-Sealing Techniques in a Simulated Model
نویسندگان
چکیده
منابع مشابه
Comparison of bag-valve-mask hand-sealing techniques in a simulated model.
STUDY OBJECTIVE Bag-valve-mask ventilation remains an essential component of airway management. Rescuers continue to use both traditional 1- or 2-handed mask-face sealing techniques, as well as a newer modified 2-handed technique. We compare the efficacy of 1-handed, 2-handed, and modified 2-handed bag-valve-mask technique. METHODS In this prospective, crossover study, health care providers p...
متن کاملEvaluation of bag-valve-mask ventilation by paramedics in simulated chemical, biological, radiological, or nuclear environments.
INTRODUCTION Bag-valve-mask ventilation is a key component of life support, but only one handheld resuscitator is designed to operate in contaminated or toxic atmospheres. METHODS After Institutional Review Board approval, the efficacy of this device was evaluated. The distal trachea of a Laerdal Airway Management Trainer was connected to a mechanical Draeger Volumeter 3000, to enable determi...
متن کاملOn - Bag - Valve Mask Ventilation ACEP
The management of the emergency airway is continually evolving with the introduction of new airway devices. There is a large body of literature regarding a variety of rescue devices and algorithms for managing the difficult airway. Despite these important advances in emergency airway management, it is imperative for the emergency physician to be facile at basic airway maneuvers. Bag-valve mask ...
متن کاملcomparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولComparison of four techniques on facility of two-hand Bag-valve-mask (BVM) ventilation: E-C, Thenar Eminence, Thenar Eminence (Dominant hand)-E-C (non-dominant hand) and Thenar Eminence (non-dominant hand) – E-C (dominant hand)
Introduction: Bag-valve-mask (BVM) ventilation is the first and important part of the airway management. The aim of present study was to evaluate the quality of four different BVM ventilation techniques - E-C, Thenar Eminence, Thenar Eminence (Dominant hand)-E-C (Non dominant hand), and Thenar Eminence (Non dominant hand)-E-C (Dominant hand) - among two novice and experienced groups. Methods: I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Emergency Medicine
سال: 2014
ISSN: 0196-0644
DOI: 10.1016/j.annemergmed.2013.07.014