Comparison of automated Difco ESP blood culture system with biphasic BBL Septi-Chek system for detection of bloodstream infections in pediatric patients

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disea...

متن کامل

Four-day incubation period for blood culture bottles processed with the Difco ESP blood culture system.

Blood culture records from 1994 to 1995 from five U.S. medical centers all using the Difco ESP continuous monitoring blood culture system were reviewed retrospectively. Among a total of 7,362 isolates of bacteria and yeasts, only 0.1% of possibly significant isolates would have been missed had blood cultures been routinely incubated for 4 days instead of the 5 days recommended by the manufactur...

متن کامل

Comparison of the Bactec Peds Plus pediatric blood culture vial with Roche pediatric Septi-Chek for blood cultures from pediatric patients.

Equal volumes of blood from 4,112 blood cultures were inoculated into one Bactec Peds Plus bottle and one Roche Septi-Chek bottle. There were no significant differences in the recoveries of bloodstream pathogens. Initial detection occurred earlier with Bactec Peds Plus, while growth on solid media occurred earlier with Roche Septi-Chek.

متن کامل

Blood culture-based detection of bloodstream infections

Bloodstream infections (BSIs) are associated with adverse clinical and health-economic outcomes [1,2]. Th irty to forty percent of all cases of severe sepsis and septic shock are culture-proven BSIs, for which there is a rapid decline in survival rates in cases where inadequate antimicrobial therapy is administered within the fi rst 24 hours [3,4]. As a consequence, clinicians often resort to e...

متن کامل

Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

Two commercially available agar slide blood culture systems, Septi-Chek (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.) and VACUTAINER agar slant (Becton Dickinson [BD] Vacutainer Systems, Rutherford, N.J.), were compared in 5,628 paired blood cultures from adult patients. The systems were inoculated with equal volumes (5 ml) of blood. There was no statistically significant diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 1995

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.33.5.1084-1088.1995