Comparison between Gradient Echo T2.WHITE STAR. Weighted Images and Fast Spin Echo T2 Weighted Images in Diagnosing Rotator Cuff Tears.
نویسندگان
چکیده
منابع مشابه
comparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences
background: nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis. objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...
متن کاملComparison of spin-echo and gradient-echo T1-weighted and spin-echo T2-weighted images at 3T in evaluating term-neonatal myelination.
SUMMARY A prior clinical report of 3T MR imaging in subsequently healthy very premature neonates imaged at term-equivalent age found that both gradient recalled-echo-T1WI and spin-echo-T2WI showed higher rates of myelinated structures, compared with spin-echo-T1WI. The current study set out to assess those rates on the same sequences at 3T in term neonates and thus consisted of 16 term neonates...
متن کاملBrain microhemorrhages detected on T2*-weighted gradient-echo MR images.
BACKGROUND AND PURPOSE Multifocal microhemorrhages have been reported to be commonly found in the brain of patients with systemic hypertension and spontaneous brain hemorrhage. The factors associated with these lesions detected on T2*-weighted gradient-echo images were examined to determine whether these lesions serve to indicate different types of microangiopathy and to predict a patient's ris...
متن کاملA fast spin-echo multi gradient-echo sequence to reduce distortions on T2-weighted images at high field
INTRODUCTION Susceptibility-induced magnetic field and chemical shift increase image distortion at high field. For a 2D fast spin echo (FSE) sequence used to obtain T2 contrast, the anatomy is distorted in the readout direction generating hypoand hyper-intense signals close to interfaces limiting the precision for morphological studies as well as generating an ambiguous contrast. Increasing the...
متن کاملComparison of gradient-recalled-echo and T2-weighted spin-echo pulse sequences in intramedullary spinal lesions.
Nineteen consecutive patients with spinal intramedullary lesions were studied on a 1.5-T system to compare the quality of T2-weighted spin-echo and gradient-recalled-echo (GRE) pulse sequences. Direct comparisons were made in the sagittal and/or axial planes. Twenty-four studies were performed in the 19 patients. The gradient echoes were usually performed at 300/14 (TR/TE) with a flip angle of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 1999
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.48.904