Comparing the Accuracy of Four Intraocular Lens Formulas in Eyes with Two Types of Widely Used Monofocal Lens Implants

نویسندگان

چکیده

The present study aimed to compare the accuracy of intraocular lens calculation formulas Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T in prediction postoperative refraction for two widely used monofocal implants: SN60WF ZCB00. All eyes were divided based on axial length (<22 mm, 22–24.5 >24.5 mm) type. mean median absolute refractive error (AE) calculated all four formulas, using manufacturer-recommended constants as well optimized constants. subgroup analysis showed that II formula had smallest three groups (with short, medium, long length) before after factor optimization, 1 best results (of medium length), one short group, AL group A-constant optimization. This hints at versatility formula, a fourth-generation is now available most optical biometers provides useful tool lengths even without constant

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.

Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...

متن کامل

assessment of hoffer correction factor for biometry in eyes with phakic intraocular lens implants

purpose: to assess hoffer correction factor in measurement of axial length (al) in eyes with phakic iol implants. methods: in this descriptive historical cohort study, axial length was measured by ultrasound (us) and iol master in both phakic and pseudophakic modes in 24 eyes of 14 patients with artisan intraocular lenses (iols) implanted for refractive purposes, hoffer’s suggested formula for ...

متن کامل

Retinal images in optomechanical eye model with monofocal intraocular lens

Intraocular lens (IOL) is an artificial lens implanted into the eye. It usually replaces the existing crystalline lens, which is clouded over due to a cataract. In order to evaluate the optical performance of different IOLs an optomechanical model of human eye was developed. This model closely reproduces anatomical and optical properties of the average human eye. This makes it possible to measu...

متن کامل

Intraocular lens calculation accuracy limits in normal eyes.

PURPOSE To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. SETTING Eye hospitals in Germany, Denmark, and Austria. METHOD Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was p...

متن کامل

Scleral fixation of a posterior chamber intraocular lens in a patient with two dislocated lens implants.

PURPOSE To report the clinical findings and management of a case of two consecutive intraocular lenses (IOLs) dislocated into the vitreous cavity after complicated cataract surgery. METHODS Review of clinical findings and treatment. RESULTS A 69-year-old man sought treatment for posterior chamber IOL dislocation. The patient reported a significant loss of visual acuity in the right eye for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Photonics

سال: 2022

ISSN: ['2304-6732']

DOI: https://doi.org/10.3390/photonics9080567