Comparing rates of atrioesophageal fistula with contact force-sensing and non-contact force-sensing catheters: analysis of post-market safety surveillance data
نویسندگان
چکیده
منابع مشابه
Contact Sensing from Force Measurements
This paper addresses contact sensing, i.e. the problem of resolving the location of a contact, the force at the interface and the moment about the contact normals is presented. Called \intrinsic" contact sensing for the use of internal force and torque measurements, this method allows for practical devices which provide simple, relevant contact information in practical robotic applications. Suc...
متن کاملComparative efficacy and safety of contact force-sensing catheter and second-generation cryoballoon ablation for atrial fibrillation: a meta-analysis
This meta-analysis compared the efficacy and safety of the contact force (CF)-sensing catheter and second-generation cryoballoon (CB) ablation for treating atrial fibrillation (AF). Six controlled clinical trials comparing ablation for AF using a CF-sensing catheter or second-generation CB were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastr...
متن کاملModeling Collision Sounds: Non-linear Contact Force
A model for physically based synthesis of collision sounds is proposed. Attention is focused on the non-linear contact force, for which both analytical and experimental results are presented. Numerical implementation of the model is discussed, with regard to accuracy and efficiency issues. As an application, a physically based audio effect is presented.
متن کاملForce‐Sensing Catheters During Pediatric Radiofrequency Ablation: The FEDERATION Study
BACKGROUND Based on data from studies of atrial fibrillation ablations, optimal parameters for the TactiCath (TC; St. Jude Medical, Inc) force-sensing ablation catheter are a contact force of 20 g and a force-time integral of 400 g·s for the creation of transmural lesions. We aimed to evaluate TC in pediatric and congenital heart disease patients undergoing ablation. METHODS AND RESULTS Compr...
متن کاملDesign, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force
This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Interventional Cardiac Electrophysiology
سال: 2019
ISSN: 1383-875X,1572-8595
DOI: 10.1007/s10840-019-00653-5