Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® IQ ReSTOR® Multifocal IOL SN6AD1
نویسندگان
چکیده
منابع مشابه
Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum ...
متن کاملVisual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.
PURPOSE To compare the visual acuity and contrast sensitivity in eyes with the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon) and eyes with the monofocal AcrySof SA60AT IOL. SETTING Policlinico Umberto I, Department of Ophthalmology, Rome, and private clinical practice, Rome, Italy. METHODS One hundred eyes had phacoemulsification cataract extraction and implantation of a ReSTOR m...
متن کاملOptical bench performance of AcrySof® IQ ReSTOR®, AT LISA® tri, and FineVision® intraocular lenses
PURPOSE To compare the resolution and optical quality of the ReSTOR(®) +3.0 D and ReSTOR +2.5 D multifocal intraocular lenses (IOLs) with the AT LISA(®) tri and FineVision(®) trifocal IOLs. METHODS Resolution, image quality, and photic phenomena were evaluated in the AcrySof(®) IQ ReSTOR +3.0 D and +2.5 D multifocal IOLs and compared with the AT LISA tri 839MP and FineVision Micro F12 trifoca...
متن کاملResidual Astigmatism Threshold and Patient Satisfaction with Bifocal, Trifocal and Extended Range of Vision Intraocular Lenses (IOLs)
Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Arquivos Brasileiros de Oftalmologia
سال: 2016
ISSN: 0004-2749
DOI: 10.5935/0004-2749.20160050