Comparative study of heat transfer enhancement using different fins in semi-circular absorber tube for large-aperture trough solar concentrator
نویسندگان
چکیده
An improved evacuated absorber tube (AT) design consisting of a semi-circular is proposed for large-aperture parabolic trough concentrator. The also contains flat-plate radiation shield in the vacuum part glass cover. To enhance heat transfer AT, different fins geometries added to bottom AT were analyzed here. Compared an without fins, thermal efficiency could be increased from 75.7% 76.9% with short and thick fin 77.3% long thin flow velocity range 0.4–1.5 m/s. finned shows better enhancement transfer, but performance factor accounting frictional losses higher fin. Simultaneously, increasing number would not improve much performance.
منابع مشابه
Investigation of Heat Transfer Coefficient Enhancement for CuO/TiO2 Nanocomposite in a Tube Heat Exchanger
In order to improve the efficiency and rate of heat transfer in heat exchangers, various techniques such as increasing the heat transfer coefficient are proposed. This study is devoted to the investigation of heat transfer coefficient variations due to the addition of CuO, TiO2 and CuO/TiO2 nanoparticles into a shell and tube heat exchanger. CuO/TiO2 nanocomposite was synthesized using mechanic...
متن کاملNormalization of Various Phase Functions for Radiative Heat Transfer Analysis in a Solar Absorber Tube
Taylor & Francis makes every effort to ensure the accuracy of all the information (the “Content”) contained in the publications on our platform. However, Taylor & Francis, our agents, and our licensors make no representations or warranties whatsoever as to the accuracy, completeness, or suitability for any purpose of the Content. Any opinions and views expressed in this publication are the opin...
متن کاملAn Experimental Study on Evacuated Tube Solar Collector using Therminol D-12 as Heat Transfer Fluid Coupled with Parabolic Trough
An evacuated tube solar collector using therminol D-12 as heat transfer fluid coupled with parabolic trough is studied in this paper. An experimental set-up was constructed to study the performance of evacuated tube collector with therminol D-12 as heat transfer fluid. The parabolic trough is coupled with evacuated tube collector for better performance. In the traditional solar collectors water...
متن کاملNumerical simulation of laminar convection heat transfer from an array of circular perforated fins
The present paper reports the laminar fluid flow and heat transfer of a heated array of circular-perforated and solid fins mounted over a flat surface using the finite-volume method. One to four circular cross-sectional perforations are made along the length of the fins. The SIMPLE algorithm is used for pressure-velocity coupling and the second order upwind technique is employed to discreti...
متن کاملNatural convection heat transfer in V-trough solar concentrators
The use of V-trough concentrators offers a simple approach to increasing the radiation incident on a solar receiver; this is particularly useful for increasing the temperature in thermal systems. However in order to accurately predict the performance of thermal systems under concentrated radiation, there is a need to understand the heat loss from them. This study experimentally shows that, for ...