Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis
نویسندگان
چکیده
منابع مشابه
Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis.
OBJECTIVES Most studies that clinically validated peri-ictal SPECT in intractable partial epilepsy had used technetium-99m-hexamethylpropylene amine oxime (99mTc-HMPAO or 99mTc-exametazime) as the radiopharmaceutical. Because of some theoretical advantages, technetium-99m-ethyl cysteinate diethylester (99mTc-ECD or 99mTc-bicisate) is increasingly being used instead. This study compares unstabil...
متن کاملDetermination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging
Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...
متن کامل99mTc-bicisate and 99mTc-HMPAO SPECT imaging in early spontaneous reperfusion of cerebral embolism.
Two patients with a cerebral embolism were evaluated by using both 99mTc-ethyl cysteinate dimer (ECD, or Bicisate) and 99mTc-hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). In one patient, 99mTc-ECD SPECT images revealed hypoactivity in a reflow hyperemic area where an infarct was seen later on CT scans. In another patient, a reperfused area showed hyp...
متن کاملDynamic and static 99mTc-ECD SPECT imaging of subacute cerebral infarction: comparison with 133Xe SPECT.
UNLABELLED 99mTc-ethylcysteinate dimer (99mTc-ECD) SPECT imaging reportedly fails to show reflow hyperemia in patients with subacute stroke. This study attempts to determine the clinical usefulness of dynamic 99mTc-ECD SPECT in evaluating regional blood flow in subacute cerebral infarction and the kinetic behavior of 99mTc-ECD in infarct areas. METHODS 133Xe and consecutive dynamic and static...
متن کاملdetermination of the optimum filter for qualitative and quantitative 99mtc myocardial spect imaging
background: butterworth, gaussian, hamming, hanning, and parzen are commonly used spect filters during filtered back-projection (fbp) reconstruction, which greatly affect the quality and size accuracy of image. materials and methods: this study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μci/ml (0.148 mbq/ml) 99mtc conc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Neurology, Neurosurgery & Psychiatry
سال: 1999
ISSN: 0022-3050
DOI: 10.1136/jnnp.66.3.331