Comparative Measurement of Sensor Performance by Partial Discharge in Full-Scale 275kV Gas Insulated Transmission Line

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears

With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD) signal generated in GIS spacers based on discrete wavel...

متن کامل

UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology

The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in col...

متن کامل

Comparison and Analysis of On-line Partial Discharge Measurement Methods for Gas Insulation Substation

In this paper, we compare and analyze the signals of acoustic emission (AE) sensor, high-frequency current transformer (HF-CT) and capacitive coupled (CC) sensor inspection methods when they are used to detect the partial discharge (PD) in gas isolation substations (GIS). The PD location feasibility of the AE method is also studied. In general, the leakage currents are measured by using the HF-...

متن کامل

Status Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance

Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment. It uses sulphur hexafluoride gas as its insulant and coolant because of its high dielectric strength and excellent arc quenching ability. Gas insulated switchgear i...

متن کامل

Feature Selection for Partial Discharge Severity Assessment in Gas-Insulated Switchgear Based on Minimum Redundancy and Maximum Relevance

Scientific evaluation of partial discharge (PD) severity in gas-insulation switchgear (GIS) can assist in mastering the insulation condition of in-service GIS. Limited theoretical research on the laws of PD deterioration leads to a finite number of evaluation features extracted and subjective features selected for PD severity assessment. Therefore, this study proposes a minimum-redundancy maxim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEJ Transactions on Power and Energy

سال: 1997

ISSN: 0385-4213,1348-8147

DOI: 10.1541/ieejpes1990.117.8_1197