Comparative gait analysis of patients with different design of total knee arthroplasty
نویسندگان
چکیده
Introduction/Objective. The essence of the treatment degenerative knee joint diseases is pain relief, restoring motion range and stability joints. Methods. In this study, 35 patients participated after having surgery joint. had a posterior-stabilized (PS) endoprosthesis in one joint, posterior cruciate ligament retaining (CR) other. Kinematic data was collected using 3D optical system for tracking fluorescent markers time. Based on these data, following parameters were determined: degree flexion, mediolateral (ML) translation, lateral gap, medial angle change between transtibial transfemoral axes. Results. results show more pronounced flexion with PS prosthesis compared to CR prosthesis. Also, negligible values ML gap both types prostheses. Using non-parameter Wilcoxon test, substantial difference axes confirmed, that is, angles Conclusion. This study shows there no great use or designs endoprostheses. Better behavior established implantation endoprosthesis. conclusion confirmed by position transversal tibia femur.
منابع مشابه
Gait analysis of elderly women after total knee arthroplasty
[Purpose] The purpose of this study was to investigate ability and muscle activities of elderly women after total knee arthroplasty (TKA) and compare them with those of healthy ones. [Subjects and Methods] Fifteen female patients with TKA due to advanced degenerative arthritis of the measured on knee joint and 19 healthy elderly females participated. Tibiofemoral angles of TKA patients were usi...
متن کاملGait after unilateral total knee arthroplasty: frontal plane analysis.
After unilateral total knee arthroplasty (TKA), osteoarthritis (OA) in the non-operated knee often progresses. The altered gait mechanics exhibited by patients after TKA increase the loading on the non-operated knee and predispose it to disease progression. Therefore, our objective was to examine the potentially detrimental changes in frontal plane kinetics and kinematics during walking in pati...
متن کاملDIFFERENT REFERENCES FOR VALGUS CUT ANGLE IN TOTAL KNEE ARTHROPLASTY
This was Presented in 5th International congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملGait Analysis of Conventional Total Knee Arthroplasty and Bicruciate Stabilized Total Knee Arthroplasty Using a Triaxial Accelerometer
One component of conventional total knee arthroplasty is removal of the anterior cruciate ligament, and the knee after total knee arthroplasty has been said to be a knee with anterior cruciate ligament dysfunction. Bicruciate stabilized total knee arthroplasty is believed to reproduce anterior cruciate ligament function in the implant and provide anterior stability. Conventional total knee arth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Srpski Arhiv Za Celokupno Lekarstvo
سال: 2021
ISSN: ['0370-8179', '2406-0895']
DOI: https://doi.org/10.2298/sarh200706046p