Comparative Feasibility Studies of High Voltage Circuit Breaker Operating in the LFAC System With Different Frequencies
نویسندگان
چکیده
With the development of flexible low frequency transmission technology following improvement offshore wind power transmission, it is great significance to investigate operation adaptability main equipment especially under conditions. A comparative study was performed in present work discuss dynamic performance a 252 kV/50 kA puffer-type circuit breaker influenced by system operational frequency. Since decreased would result longer arc duration, pre-designed driving mechanism with characteristics high speed control proposed and compared conventional unit. Moreover, as one reasonable indicators evaluate interruption breaker, critical rate rise recovery voltage (RRRV) that can withstand after extinguishment different frequencies were computationally obtained an established model. The effects change on during comprehensively discussed well could reasonably provide technical optimisation for low-frequency-based further engineering applications analysing its feasibility.
منابع مشابه
Development of an Overall Condition Monitoring System of High Voltage SF6 Circuit Breaker
With the rapid development of arts of sensors and IT, on-line monitoring of circuit breaker is now desirable and practical for electric power utilities. This paper describes a set of overall on-line monitoring systems that was developed to control and monitor the condition of SF6 circuit breaker with different type of sensors and microcomputer based controller. The aim of the developed system i...
متن کاملOn-line Monitoring System based on Vibration Signal of High Voltage Circuit Breaker
High voltage circuit breaker is one of the most important switch apparatus in electrical power system. It play a role in the switch control, which can be used to switch the operating mode during normal operation (the equipment run or quit). In order to ensure the normal operation of the grid, it can be removed quickly when a malfunction on the device or circuit. Real-time online monitoring of h...
متن کاملcomparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods
هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...
15 صفحه اولSF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress
In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...
متن کاملthe effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill
this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2022
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2022.3203191