Background: Infection control is a major issue in medicine and dentistry because of concern over communicable diseases transmitted health care settings. The present study was conducted for comparatively evaluating various Cold Sterilization Techniques on Carbide Burs Diamond Points. Materials & methods: Two disinfectant solutions were used: 2% glutaraldehyde 5.2% sodium hypochlorite. group formed Group A while diamond burs the B. Collection total 40 tooth samples done .i.e. 20 each ; further both groups consisted two subgroups as per type solution. bacterial count evaluated before after disinfection. All results recorded analysed by SPSS software. Results: Sodium hypochlorite sterilization technique slightly better comparison to Glutaraldehyde technique. Also carbide associated with less microbial growth. Conclusion: clinical usage.
منابع مشابه
Evaluation of Different Sterilization Methods on the Uniformity of Diamond Dental Burs and the Change in the Cutting Edge of Carbide Burs by Electron Microscopy
Introduction: Dental burs are one of the most commonly used materials in dental offices and have, therefore, the highest risk of cross-contamination. Accordingly, sterilization of dental burs is highly recommended. Using the electron microscopy, this study aimed to evaluate the results of different sterilization methods on the uniformity of diamond dental burs and the change in the cutting edge...
متن کاملInfluence of Microwave Sterilization on the Cutting Capacity of Carbide Burs
OBJECTIVE This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. MATERIAL AND METHODS Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutt...
متن کاملComparative efficiency testing 330 carbide dental burs utilizing Macor substrate.
Traditionally, it has been difficult to compare the clinical performance of carbide dental burs. The purpose of this laboratory study was to investigate the comparative cutting efficiency of number 330 dental burs from six manufacturers. These burs were tested utilizing custom-built equipment consisting of a frictionless air sled to which the Macor substrate was attached. The substrate was fed ...
متن کاملcomparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولtransference of imagery: a comparative formalistic study of shakespeares hamlet and its two persian translations
هدف از این تحقیق بررسی انتقال صور خیال هملت در دو ترجمه ی فارسی آن از نظر فرمالیستی بود. برای بدست آوردن داده-های مورد نیاز، 130 نمونه استعاره، مجاز، ایهام، کنایه و پارادوکس در متن اصلی مشخص شده و سپس بر اساس مدل نیومارک (1998) برای ترجمه ی استعاره یا بطور کلی زبان مجاز با معادل های فارسی شان مقایسه گردیدند. این تحقیق بر آن بود تا روش های استفاده شده برای ترجمه هر کدام از انواع زبان مجاز ذکر شد...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Health Sciences (IJHS)
سال: 2022
ISSN: ['2550-6978', '2550-696X']
DOI: https://doi.org/10.53730/ijhs.v6ns5.9939