Comparative evaluation of accuracy of ipex, root zx mini, and epex pro apex locators in teeth with artificially created root perforations in presence of various intracanal irrigants
نویسندگان
چکیده
منابع مشابه
The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...
متن کاملA Comparative Evaluation of Accuracy of the Root Zx Electronic Apex Locator in the Presence of Different Irrigants
Objective: The aim of this study is to evaluate the accuracy of Root ZX in determining working length in presence of 2% chlorhexidine and 5% sodium hypochlorite. Material and Methods: Thirty extracted, single rooted, single canal human teeth were used. Teeth were decoronated at CEJ and actual canal length determined. Then working length measurements were obtained with Root ZX in presence of 2% ...
متن کاملEx vivo accuracy of Root ZX II, Root ZX Mini and RomiApex A-15 apex locators in extracted vital pulp teeth.
The objective of this study was to compare, ex vivo, the accuracy of three electronic apex locators (EALs), Root ZX II, Root ZX Mini and RomiApex A-15, in detecting the apical foramen (AF). Forty extracted single-Rooted human teeth with vital pulp were used in this study. After access preparation, the Root canal length of each tooth was measured by placing a #10 file until the tip was visible a...
متن کاملcellular behavior and scanning electron microscope evaluation of pro-root mta, root mta and modified mta on fibroblast l929
چکیده ندارد.
15 صفحه اولAccuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.
INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Endodontic Journal
سال: 2020
ISSN: 2548-0839
DOI: 10.14744/eej.2019.07279