Comparative Efficacy of Limited Contact-Dynamic Compression Plate and Dynamic Compression Plate for Repair of Diaphyseal Femoral Fracture in Dogs
نویسندگان
چکیده
منابع مشابه
Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse
Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...
متن کاملPlate fixation of clavicle fractures: a comparative study between Reconstruction Plate and Dynamic Compression Plate.
This study aimed at comparing the results of clavicular fracture fixation with AO Reconstruction (Recon) plate and Dynamic Compression Plate (DCP). The case notes of 39 patients with 40 acute and chronic clavicular fractures were retrospectively reviewed. The indications for fixation for acute cases comprised open fractures, the presence of sufficient skin tenting to risk skin integrity, neurov...
متن کاملComparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate
Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly ...
متن کاملInternal fixation of fractures of both bones forearm: Comparison of locked compression and limited contact dynamic compression plate
BACKGROUND The locking compression plate (LCP) with combination holes is a newer device in fracture fixation. We undertook a study comparing the LCP with limited contact dynamic compression plate (LC-DCP) in the treatment of diaphyseal fractures of both bones of the forearm. MATERIALS AND METHODS This is a prospective comparative study, 36 patients (18 in each group) with fractures of both th...
متن کاملMinimally Invasive Plate Osteosynthesis with Conventional Compression Plate for Diaphyseal Tibia Fracture.
The diaphyseal tibia fracture is best treated with intramedullary nail but in some cases where the nail is not applicable, plate fixation will be the next option of fixation. The extensile anterior approach is normally used for conventional compression plate fixation in tibia shaft fractures. The extensive surgical dissection may devitalizes the bony fragments and interfere with the fracture un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Animal and Veterinary Sciences
سال: 2014
ISSN: 2307-8316
DOI: 10.14737/journal.aavs/2014/2.5.296.301