Compact high-temperature shear-cell furnace for in-situ diffusion measurements
نویسندگان
چکیده
منابع مشابه
Compact high-temperature cell for Brillouin scattering measurements
A compact ceramic high-temperature cell for Brillouin spectroscopy was designed and tested. The cell can be mounted onto a threeor four-circle goniometer and allows collection of the full set of elastic constants of minerals to temperatures in excess of 1500 K from samples with dimensions of 1003100320 mm or smaller. As a test of the instrument the single-crystal elastic constants of MgO were m...
متن کاملA compact bellows-driven diamond anvil cell for high-pressure, low-temperature magnetic measurements.
We present the design of an efficient bellows-controlled diamond anvil cell that is optimized for use inside the bores of high-field superconducting magnets in helium-3 cryostats, dilution refrigerators, and commercial physical property measurement systems. Design of this non-magnetic pressure cell focuses on in situ pressure tuning and measurement by means of a helium-filled bellows actuator a...
متن کاملA High-temperature Powder Diffraction Furnace
A new high-temperature XRD instrument, utilizing multilayer optics and a custom furnace, has been developed to maximize sensitivity and minimize problems associated with sample displacement. This paper will describe the technical specifications of the new instrument, and will present temperature calibration with standard reference materials and measurement of phase evolution in an industrial gl...
متن کاملA versatile high-temperature furnace for neutron four-circle diffractometers
2014 The design and performance of a versatile closed, light (0,9 kg), high temperature furnace adapted to the needs of a neutron four-circle diffractometer is reported. It operates between 330 and 1 200 K with a long term stability of better than 0.05 K. There are few restrictions on the movement of the circles; only the 03A6-range is limited to 200°. The furnace operates under high vacuum (ty...
متن کاملHigh temperature dilatation measurements by in situ laser interferometry under high magnetic field.
This article contains a description of a laser interferometer coupled with a furnace for in situ dilatation measurements under high magnetic field. The apparatus fits an 18 T superconducting magnet with a 32 mm diameter room temperature bore. This optical method was chosen for dilatation measurements because it is not perturbated by the magnetic field. The measured sample can be heated up to 15...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2011
ISSN: 1742-6596